External Limit Switch Connection
The controller may be used with an external pressure limit switch or sensor to provide
demand-cleaning operation. A three pin terminal block provides connection for exter-
nal high and low limit switches. A simple on-off system can be established with a sin-
gle pressure switch connected to the high limit input. Better control can be achieved
with a high and low limit switch/gage such as the Dwyer Photohelic
®
pressure gage.
The switches must be isolated contacts between the high or low limit input and the
common connection. The wiring from the switches must be two or three wires with no
other connections made to these. The common line must not be connected to equip-
ment ground or protective ground, since these may introduce electrical noise and
cause improper operation or possible damage to the control board. The operation of
these inputs is summarized as follows:
Operating Modes
Continuous Cycle Mode
The DCT600 has two operating modes available for different applications. Starting
with the most basic mode, it is capable of operating in a continuous cleaning cycle.
This can be initiated by placing a jumper between the high limit input and the com-
mon connection. Two setup parameters control operation: time off, time on. Time on
and time off specifically deal with the solenoid on time and the time interval between
the end of the on pulse and the start of the next.
Demand Mode
Demand mode operation can be configured using the high limit and low limit inputs.
A simple on-off system can be setup with a single pressure switch connected to the
high limit input. Better control can be achieved with a high and low limit switch set
such as is provided in the Photohelic
®
pressure gage. In this on-demand mode, time
on and time off may be programmed to define the cleaning cycle. When the cleaning
cycle is completed, the controller will continue the cycle until the last channel is
pulsed. The next cleaning cycle will always start on channel 1. A factory installed
option is available. A factory installed option is available that will not clean to the end
of a cycle, but rather stop where the cleaning cycle ended. The next demand for
cleaning will start where the last cleaning cycle left off.
System Setup
Last Channel Selection DCT604, DCT606, DCT610
A jumper connector is provided on the DCT610, DCT606, and DCT604 to select the
last channel used. Place the jumper on the two pins corresponding to the last chan-
nel used in the installation.
Last Channel Selection DCT622, DCT632
The DCT622 and DCT632 use a set of 5 switches to select the last channel. If the
selected last channel is greater than the number of channels available then the con-
troller will cycle through only the available channels. The following table defines the
switch settings for each of the last channel selections. For convenience this table is
also provided on the board below the switch.
Time Off and Time On Setup
Time off defines the period of time between solenoid activations when no channels
are enabled. This value may be set between 1 second and 200 seconds with a reso-
lution of 1 second. Time on defines the solenoid on time. The value may be set
between 50 msec and 500 msec with a resolution of 10 msec. If adjustments are
made while the system is in operation, the new setting will take effect in the following
solenoid cycle. Do not use excessive force to turn the potentiometers. This will dam-
age the unit. A factory installed option is available for a time on range of 0.05 to 10
seconds.
0.31 TYP [7.87]
4 PLACES
7.73
[196.3]
8.88
[225.6]
4.00 TYP
[101.6]
5.74
[145.8]
4.45
[113.0]
4.00
[101.6]
Weatherproof Enclosure Option
DCT604, DCT606, DCT610
0 = Off, 1 = On
Current
Operation
Hold
Hold or Run
Hold
Hold
Run
Hold
Run
Low Limit
Switch
Open
X
Ø
Closed
Closed
Closed
High Limit
Switch
Open
Closed
Open
Ø
Ø
Open
Next
Operation
Hold
Run
Hold
Run
Run
Run
Hold
Ø – Transition from open to closed
≠ – Transition closed to open
X – Either open or closed
Channel
32
31
30
29
28
27
26
25
24
23
22
Switch
00000
00001
00010
00011
00100
00101
00110
00111
01000
01001
01010
Channel
21
20
19
18
17
16
15
14
13
12
11
Switch
01011
01100
01101
01110
01111
10000
10001
10010
10011
10100
10101
Channel
10
9
8
7
6
5
4
3
2
1
Switch
10110
10111
11000
11001
11010
11011
11100
11101
11110
11111
E-99:DCT500 bulletin 7/8/09 8:17 AM Page 3