Series APV Piston Vibrators that are air cushioned help to provide low
noise character. This makes it suitable for quiet area application. It is a
good solution to prevent clogs on tank walls and material delivery prob-
lems. Piston impact types also can help to get rid of rust and material
accumulated inside pipes. Direct impact on a tank with low specific grav-
ity and high moisture material inside will help prevent material build-up
and pipe clog or rust.
WORKING PRINCIPLE APV-C
There are air-breathing tubes located in both ends of the cylinder.
Compressed air pushes the piston from one side to the other side.
Vibration power arises as the piston moves back and forth in the body.
Air cushion at both ends produced by the to-and-fro compression will
keep the piston from striking the body. Therefore, the piston will not pro-
duce much noise.
WORKING PRINCIPLE APV-I
There are air-breathing tubes located in both sides of the cylinder.
Compressed air pushes the piston away from one side and to the other
side. Vibration arises when the piston moves back and forth in the body.
Air cushion at the top end is produced by the to-and-fro compression.
This will keep the piston from striking onto the body top. The piston will
strike directly on the bottom side of the body to produce a strong impact.
Series APV Piston Vibrator
Specifications - Installation and Operating Instructions
Bulletin P-10
PROXIMITY CONTROLS
Phone: 219/879-8000 www.dwyer-inst.com
A DIVISION OF DWYER INSTRUMENTS, INC.
Fax: 219/872-9057 e-mail: [email protected]
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.
A
IN
O
UT
D
ØC
ØH
Ø
B
87 psi (6 bar)
126 (560)
161 (715)
231 (1030)
3996 (17776)
6048 (26904)
8276 (36816)
(l/min)
8.12 (230)
8.79 (249)
9.50 (269)
8.8 (250)
9.5 (270)
10.6 (300)
lb (kg)
1.98 (0.9)
4.19 (1.9)
9.92 (4.5)
2.2 (1.0)
4.6 (2.1)
10.6 (4.8)
Air
Consumption
Weight
Model
APV-C1
APV-C2
APV-C3
APV-I1
APV-I2
APV-I3
29 psi (2 bar)
1765
1333
1000
1973
1744
1277
58 psi (4 bar)
2308
1677
1200
2885
2459
1875
87 psi (6 bar)
2857
1875
1340
3571
3000
1973
29 psi (2 bar)
44 (195)
62 (275)
91 (404)
1818 (8086)
3245 (14443)
3470 (15434)
58 psi (4 bar)
85 (380)
119 (531)
175 (780)
3044 (13542)
4934 (21948)
7799 (34692)
Frequency (V.P.M.)
Pressure Input
Force lbf (N)
Pressure Input
V.P.M. = vibrations per minute
SPECIFICATIONS
Temperature Limit: 212°F (100°C).
Noise Level Range: APV-C: 60-75 dBA; APV-I: 80-115 dBA.
Supply Pressure: 29 to 87 psi (2 to 6 bar).
Air Consumption: See model chart.
Air Connection: 1/8˝ BSPT female with 1/4˝ OD push to connect
adapter on APV-C1 and APV-I1; 1/4˝ BSPT female with 1/4˝ OD push to
connect adapter on APV-C2, APV-C3, APV-I2 and APV-I3. Also includes
muffler for exhaust port.
Housing Material: Aluminum.
M
odel
A
PV-C1, I1
A
PV-C2, I2
A
PV-C3, I3
A
5.43˝ (138 mm)
6.54˝ (166 mm)
8.19˝ (208 mm)
øB
3.15˝ (80 mm)
3.94˝ (100 mm)
5.51˝ (140 mm)
øC
2.36˝ (60 mm)
2.95˝ (75 mm)
4.13˝ (105 mm)
D
0
.47˝ (12 mm)
0
.63˝ (16 mm)
0
.63˝ (16 mm)
øH
0.79˝ (20 mm)
0.94˝ (24 mm)
0.94˝ (24 mm)
C
onnection
1
/8˝
1
/4˝
1
/4˝
INSTALLATION
Vibration force transmits more efficiently in a conical hopper tank as
opposed to a rectangular hopper. It is recommended that you install two
vibrators in rectangular hoppers.
1. Vibrator force can be transmitted more efficiently by using “U” shape
steel supports. It can help materials run smoother in the tank or pipe. It
also reduces tank damage accidents.
2. To avoid tank wall amplitude caused by the vibrator moving in a left or
right direction, use “U” shape steel.
3. Reinforced board is required between “U” shape steel and a thin tank
wall.
4. To increase vibration fields in a big hopper tank, criss-cross “U” shape
steel.
Attention: Vibration has to be fixed by a high tension bolt, washer, and
spring washer. Connect with a security cable if the vibrator is installed
onto a hopper.
Page view 0
1 2

Summary of Contents

Page 1 - PROXIMITY CONTROLS

Series APV Piston Vibrators that are air cushioned help to provide lownoise character. This makes it suitable for quiet area application. It is agood

Page 2

APV-C SERIESAPV-I SERIESNOTES:Various tanks are based on application requirement. Customers chooseappropriate vibrator types to meet with vario

Comments to this Manuals

No comments